Сервер Lenovo ThinkSystem SR650 V2
2U · 2 сокета LGA4189 · 32 слота DDR4
Уточнить наличие
795 657 ₽
≈ $9 642,66
- Гарантияусловия в предложении
- Доставка по РФстоимость по поставке
- Отсрочка платежапо согласованию
Характеристики
Поддерживается
- Процессорные сокеты
- 2 сокета LGA4189
- Слоты памяти
- 32 слота DDR4
- Процессоры
- Поддержка Intel Xeon Scalable 3-го поколения; 2 × LGA4189
- Тип
- DDR4
- Поддерживаемые процессоры
- Up to two 3rd Gen Intel Xeon scalable processors; ; Designed for Land Grid Array (LGA) 4189 socket; ; Up to 40 cores per socket; ; Supports 3 Intel Ultra Path Interconnect (UPI) links at 11.2 GT/s; ; Thermal Design Power (TDP): up to 270 watts; ; For a list of supported processors, see Lenovo ServerProven website .
- Поддерживаемая память
- Memory slots: 32 DIMM slots that support up to:; 32 DRAM DIMMs; ; 16 DRAM DIMMs and 16 Intel Optane Persistent Memory (PMEMs); ; ; Memory module types:; TruDDR4 3200, dual-rank, 16 GB/32 GB/64 GB RDIMM; ; TruDDR4 3200, quad-rank, 128 GB 3DS RDIMM; ; TruDDR4 2933, octal-rank, 256 GB 3DS RDIMM; ; TruDDR4 3200, 128 GB/256 GB/512 GB PMEM; ; ; Minimum memory: 16 GB; ; Maximum memory:; Without PMEMs:; 2 TB using 32 x 64 GB RDIMMs; ; 8 TB using 32 x 256 GB 3DS RDIMMs; ; ; With PMEMs:; 10 TB: 16 x 128 GB 3DS RDIMMs + 16 x 512 GB PMEMs (Memory Mode); Total 10 TB installed memory capacity, of which 8 TB (PMEMs) is used as system memory and 2 TB (3DS RDIMMs) is used as cache.; ; 12 TB: 16 x 256 GB 3DS RDIMMs + 16 x 512 GB PMEMs (App Direct Mode); Total 12 TB installed memory capacity, of which 4 TB (3DS RDIMMs) is used as system memory and 8 TB (PMEMs) is used as persistent memory for storage.; ; ; ; Note The operating speed and total memory capacity depend on the processor model and UEFI settings.; See Memory module installation rules and order for detailed information about memory configuration and setup.; For a list of supported memory options, see Lenovo ServerProven website .
- Слоты расширения модели
- Up to eight PCIe slots; ; One OCP adapter slot; ; PCIe slot availability is based on riser selection and rear drive bay selection. See Rear view and PCIe slots and PCIe adapters .
- Форм-фактор
- 2U
Возможности и базовые варианты платформы
- Габариты модели
- 2U; ; Height: 86.5 mm (3.4 inches); ; Width: With rack latches: 482.1 mm (19.0 inches); ; Without rack latches: 445.0 mm (17.5 inches); ; ; Depth: 763.7 mm (30.1 inches); Note The depth is measured with rack latches installed, but without the security bezel installed.
- Варианты дисковых отсеков
- Front drive bays:; Up to 24 x 2.5-inch hot-swap SAS/SATA/NVMe drives; ; Up to 12 x 3.5-inch hot-swap SAS/SATA/NVMe drives; ; ; Middle drive bays:; Up to 8 x 2.5-inch hot-swap SAS/SATA/NVMe drives; ; Up to 4 x 3.5-inch hot-swap SAS/SATA drives; ; ; Rear drive bays:; Up to 8 x 2.5-inch hot-swap SAS/SATA drives; ; Up to 4 x 3.5-inch hot-swap SAS/SATA drives; ; Up to two 7mm drives; ; ; Up to two internal M.2 drives; ; Note Oversubscription occurs when the system supports 32 NVMe drives using NVMe switch adapters. For details, see https://lenovopress.lenovo.com/lp1392-thinksystem-sr650-v2-server#nvme-drive-support .; For details about supported internal storage, see https://lenovopress.com/lp1392-thinksystem-sr650-v2-server#internal-storage .; For thermal information about server models with middle or rear drive bays, see Server models with middle/rear drive bays .
- Порты модели
- Front:; One VGA connector (optional); ; One USB 3.2 Gen 1 (5 Gbps) connector; ; One USB 2.0 connector with XClarity Controller management; ; One external diagnostics connector; ; One LCD diagnostics panel (optional); ; ; Rear:; One VGA connector; ; Three USB 3.2 Gen 1 (5 Gbps) connectors; ; One XClarity Controller network connector; ; Two or four Ethernet connectors on the OCP 3.0 Ethernet adapter (optional); ; One serial port (optional)
- Охлаждение модели
- Supported fan types: Standard fan (60 x 60 x 36 mm, single-rotor, 17000 RPM); ; Performance fan (60 x 60 x 56 mm, dual-rotor, 19000 RPM); ; ; Fan redundancy: N+1 redundancy, one redundant fan rotor; One CPU: five hot-swap system fans (4+1 redundancy, one redundant fan rotor); ; Two CPUs: six hot-swap system fans (5+1 redundancy, one redundant fan rotor); ; ; Note Single-rotor hot-swap fans cannot be mixed with dual-rotor hot-swap fans.; ; When the system is powered off but still plugged in to AC power, fans 1 and 2 may continue to spin at a much lower speed. This is the system design to provide proper cooling.
В таблице отдельно указаны установленная комплектация и возможности платформы. Состав поставки и условия подтверждаем в коммерческом предложении.

{ свяжитесь с нами }
Нужна консультация по этой позиции?
Оставьте контакты — специалист уточнит наличие, рассчитает стоимость и сроки поставки. Если товара нет в наличии, предложит подходящий аналог.